Tiger-Vac

Tel: (39) 051 79.53.52

Industrial Vacuum Cleaner Systems
For Bakery Oven Cleaning

rocko-at-the-oven-2Tiger-Vac is pleased to present its new line of vacuum cleaners for cleaning ovens in artistic and industrial bakeries.

Tiger-Vac’s line of vacuum cleaners ensures without dispersion, as opposed to sweeping, the recovery of powdered flour which is the leading cause of respiratory allergies in bakeries.

Tiger-Vac’s line of vacuum cleaners ensure health and safety

Tiger-Vac’s line of vacuum cleaners allow for rapid, thorough and safe cleaning of powders which cause respiratory allergies in bakeries, while still conforming, in particular, to the ATEX directives concerning high risk zones.

Different applications

  1. Single phase models TV-27, non-ATEX, and ATEX 22E with optional accessories Kit #2 are designed to recover hot powders and crumbs inside ovens.
  2. For the recovery of flour, Tiger-Vac would like to propose our single phase model EXP1-20L DT certified ATEX Category 2 Zone 21, 22 (dust) and also Zone 1,2 (gas). When equipped with optional accessories Kit #2, can be used to recover hot powders and crumbs inside ovens.

Flour is a product known to be explosive. In order to recover flour without risk, it is necessary to use a vacuum cleaner that is ATEX certified by a notified independent testing laboratory that conforms to ATEX directives concerning high risk zones.

We invite you to review the line of vacuum cleaners designed by Tiger-Vac for bakery oven cleaning and to contact us with any questions or requests for further information that you may have.

TV-27 Funciona Con Energía Eléctrica Oven Cleaning Vacuum

Información rápida

  • High Temperature Main Filter 
  • Designed for oven cleaning up to 150ºC
  • Single Phase thru-flow motor
  • Dry recovery only
  • Stainless steel Recovery Tank.  Recovery capacity of 7 gallons (26.6 liters)
  • Based on a 4-wheel dolly for easy maneuverability
  • Complete oven cleaning tool kit included.

Detalles

Tiger-Vac is pleased to present its new line of vacuum cleaners for cleaning ovens in domestic and industrial bakeries.

This unit ensures recovery without dispersion, as opposed to sweeping, the recovery of powdered flour which is the leading cause of respiratory allergies in bakeries. This unit ensures health and safety and allows for rapid, thorough and safe cleaning of these powders.

Folletos y Certificados

Name Description Download
TV-27 Brochure (Metric) Technical data for TV-27 in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
TV-27 Brochure (Imperial) Technical data for TV-27 in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
ATEX-22E (4W) Funciona Con Energía Eléctrica Seco Solamente
Power: MAX 1200 WATTS

Información rápida

ce-markex_mark II 3 D Ex tD A22 IP6X T100oC

Vacuum cleaner classified according to Dust Class B1 (BIA ZH 1/487)

Combustible dusts of the explosion classes St1, St2, St3 in Zone 22 (Previously Zone 11)

Para limpieza general .Con motor universal by-pass y proteccion td. .Con disipacion estatica y conductivo, (categoria 3-zona 22 polvo). .Para recuperacion seca solamente. .Incluye filtros desechables. Fabricado en acero inoxidable SAE 430, con el cabezal pintado. .Listo para su uso con filtros y accesoris SD incluidos. .Equipados con disipacion estatica en las ruedas. .Equipo de taladro disponible.

Detalles

.En acero inoxidable SAE430 Y el cabezal pintado. .Tiene un filtro HEPA (H14)localizado por debajo del motor. .2 filtros mas estan incluidos en el cabezal cubriendo el motor y son elegibles para IP6X. .Esta unidad contiene disipacion estatica y conductiva (categoria-3 zona 22 para polvo). .Esta unidad no puede ser utilizada para recoger polvos explosivo o conductivos ni liquidos inflamables. Ademas contiene una potente fuerza de succion que esta diseñada para aplicaciones industriales. Todos nuestrs aspiradores HEPA son probados con aerosol antes de salir de nuestras instalaciones.

Folletos y Certificados

Name Description Download
ATEX-22E (4W) Brochure (Metric) Technical data for ATEX-22E (4W) in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
ATEX-22E (4W) Brochure (Imperial) Technical data for ATEX-22E (4W) in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
EXP1-20L (DT) RE HEPA (MFS) Funciona Con Energía Eléctrica Pharma* - Dry Recovery
Power: 1000 Watts

Información rápida

ce-mark 0081 ex_mark II 2 G/D Ex d IIA T3 Ex tD A21
IP6X – T 200°C
LCIE 03 ATEX 6297

ce-mark 0081 ex_mark II 2 G/D Ex d IIA T4 Ex tD A21
IP65 – T 120°C
LCIE 03 ATEX 6297

GUARANTEED to be capable of safely recovering combustible/conductive dusts &/or flammable liquids.

IECEx Certified

  • Legally certified explosion proof/dust ignition proof by a recognized testing laboratory
  • Less than 10 Ohms of resistivity
  • Fltro HEPA - Incluido con una eficacia de 99.995% sobre 0.3 micras comprobado. IEST RP-CC001.3.H14 por MPPS segun el metodo EN 1822
  • *Cleanroom compatible.  Can be used in the pharmaceutical industry with optional stainless steel cart
  • Designed for applications where finely pulverized dust is to be recovered
  • Single phase explosion proof/dust ignition proof motor
  • Available with Manual Filter Shaker (MFS) system
  • For dry recovery only
  • All stainless steel SAE 304 construction (except cart).  Stainless steel cart available
  • Detachable recovery tank (DT).  Recovery capacity of 6.25 gallons (25 liters)
  • Equipped with an SD* polyliner and clip for easy and safe disposal of recovered materials
  • Equipped with an SD* 4-wheel cart and tool basket
  • Complete static dissipating tool kit and suction hose included

SD* Static Disspative

Detalles

All stainless steel SAE 304 construction (except cart).  Less than 10 Ohms of resistivity.  This unit is equipped with a true HEPA (H14) Filter located downstream of the motor.  This unit is cleanroom compatible and can be used in the phamaceutical industry when equipped with an optional stainless steel cart.  This unit has been designed for applications where finely pulverized dust is to be recovered.  This dry only unit contains a Manual Filter Shaker (MFS) system.  All of our HEPA vacuum cleaners are Aerosol Leak Tested before leaving our facility.

Folletos y Certificados

Name Description Download
EXP1-20L (DT) RE HEPA (MFS) Brochure (Metric) Technical data for EXP1-20L (DT) RE HEPA (MFS) in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
EXP1-20L (DT) RE HEPA (MFS) Brochure (Imperial) Technical data for EXP1-20L (DT) RE HEPA (MFS) in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
ATEX Vacuum Cleaners electrically operated singlephase T3 Certification Document descargar

 

Tool Kits

Accessories Kit no 1 for oven cleaning ø 40mm Part no 381479
oven_toolkit_1 Code#Description
1381475-HTSuction Hose Assembly, Metallic & Ceramic. 3m with 50mm hose cuff
2381478Straight Wand with full protective sleeve. 1m
3381478AStraight Wand with half protective sleeve. 1m
4381478MStraight Wand without protective sleeve. 1m
5381491Oven Flat Tool with Teflon blades
Accessories Kit no 2 for oven cleaning ø 40mm Part no 381479A
oven_toolkit_2 Code#Description
1381475-HTSuction Hose Assembly, Metallic & Ceramic. 3m with 50mm hose cuff
2381478Straight Wand with full protective sleeve. 1m
3381478AStraight Wand with half protective sleeve. 1m
4381478MStraight Wand without protective sleeve. 1m
5381491Oven Flat Tool with Teflon blades
6212359Main Filter Assembly, High Temperature, with gasket
7213186BCage for High Temperature Cloth Filter

Notes:

  • Other models with more power and larger recovery capacities are available upon request.
  • Pneumatically (air) operated models available.
  • ATEX Category 3 vacuum cleaners can be used in Zone 22 in the presence of flour but cannot be used to recover flour (please see the definition for Zone 22 in Annex I of ATEX Directive 1999/92/CE)
  • Only Category 2 vacuum cleaners designed for use in Zones 21 and 22 can be used to recover flour
  • In Zone 22, Category 2 and/or 3 vacuum cleaners can be used depending on the application required please see selection criteria in Annex II of ATEX Directive 1999/92/CE.
You are here